
Warehouse LED Lighting Retrofits
LED lighting retrofits for warehouses and distribution centres, designed around your racking, installed around your shipping schedule and backed by Think Green Solutions.

Green running man exit signs, wayfinding strips and stair edge strips that glow on stored light when the power goes out. No electricity, batteries or bulbs at the sign. Supplied, audited and installed by Think Green Solutions.


A photoluminescent exit sign absorbs light from your building's normal lighting, stores it, and glows when that light goes out. There is no electricity, battery, bulb or wiring at the sign to create its emergency glow, so a power failure or a tripped breaker does not leave the exit dark.
In Canada, photoluminescent exit signs and path marking are built and tested to CAN/ULC-S572, the national standard for photoluminescent and self-luminous exit signs and path marking systems, and the National Building Code calls for the green “running man” pictogram in place of the word EXIT.
Think Green Solutions supplies photoluminescent running man exit signs approved to CAN/ULC-S572 at the maximum 120-minute duration, rated to perform with as little as 2 foot-candles of light, and backed by the manufacturer's 25-year performance guarantee. We also supply wall wayfinding strips and stair edge strips, and handle the site audit and installation.
Everything needed to mark the way out of your building, from the exit door back along the route.
Green photoluminescent running man exit signs for exit doors, approved to CAN/ULC-S572 at the maximum 120-minute duration.
Running man signs with directional arrows that point the way along corridors and at turns in the route.
Photoluminescent strips mounted along walls that outline the path to the exit when the lights go out.
Photoluminescent strips on stair edges so each step stays visible in a stairwell that has gone dark.
A walk-through of your exits, existing signs and the lighting that charges them, and a recommendation for what to change.
Our installation teams install the signs and strips. With no wiring to run, signs mount without an electrical connection.
Photoluminescent signs only work if they are in the right places and kept charged, so every project starts with a walk-through of your building.

We check every exit, existing exit sign and path of travel, including corridors and stairwells.
We confirm that the normal lighting on each sign face is enough to keep it charged, and that it is not on a timer or motion sensor.
You get a plan for which signs to replace, where directional signs belong, and where wayfinding and stair strips will help.
Our installation teams install everything to the plan, so your building is marked from every exit door back along the route.
A traditional exit sign depends on electricity, wiring, backup batteries and lamps, all of which need upkeep and eventually replacement. A photoluminescent sign needs only the light already in your building.
No wiring, circuit or power supply at the sign, which simplifies new installs and replacements.
No bulbs, LEDs or backup batteries at the sign to fail or replace.
Stored light keeps the sign visible during a power failure, when an electrically powered sign would depend on its backup supply.
Unlike self-luminous tritium signs, photoluminescent signs glow from light they absorb, with no radioactive material to handle or dispose of.
CAN/ULC-S572 is the Canadian standard for photoluminescent and self-luminous exit signs and path marking systems. The current edition was published in 2017 and reaffirmed in 2022, and it is referenced in the National Building Code of Canada. Signs evaluated at less than the maximum viewing distance are marked with their rated viewing distance.
Since its 2010 edition, the National Building Code has called for pictogram exit signs, the green running man with directional arrows, in place of the word EXIT. The 2017 edition of CAN/ULC-S572 set the colour scheme as green on a white or lightly tinted background.
Photoluminescent signs need an external light source to charge. Some jurisdictions set a minimum light level on the sign face, such as 54 lux in Winnipeg, and some do not allow the charging light to be on an automatic timer. Requirements vary by province and municipality, so our site audit checks your building against the rules that apply to it.
Running man exit signs over exit doors, along back-of-house corridors and hung from open-truss retail ceilings, glowing on stored light with no wiring at the sign.














Contact us
Tell us about your project and we'll get back to you. Based in Cambridge, Ontario, we run lighting projects for commercial and industrial clients across Canada and the United States. Active outage or failing fixtures? Call +1 (647) 381-3733 and talk to our experts
Service area
Canada and the United States
Hours
Mon–Sat, 8am–6pm
Straight answers to the questions facility and property managers ask us about photoluminescent exit signs and path marking.
Want your exits checked? Book a site audit

LED lighting retrofits for warehouses and distribution centres, designed around your racking, installed around your shipping schedule and backed by Think Green Solutions.

LED lighting retrofits for manufacturing plants and industrial facilities, built for high ceilings and harsh environments and installed without shutting down production.

Lighting layouts and photometric design built around how each area of your building is used, as part of Think Green Solutions' turnkey projects.